Oxidation-reduction potential (ORP or REDOX) measurements are used to monitor the influent for the presence of excessive oxidizers or reducing agents. ORP is also used to monitor activated sludge and if the effluent disinfection (or reaction) by chlorine or other oxidants is still in process. Inversely, it can be used to ensure sufficient de-chlorination has occurred in effluent to safeguard environments downstream of the wastewater plant.

Read More

wastewater treatment plant tanks aeration and biological purification of sewage
  • Full Range: -1999 to +1999 mV (meter dependent)
  • Accuracy: ±0.1 mV (meter dependent)
  • Temperature Range: -5 to 135°C
  • Tuff-Tip Option
  • Custom Mechanical Assemblies Available
  • Warranty: 12 months
  • Form Factor
    • 12 mm
    • Cartridge
    • Process Body
    • Custom Options Available
  • Housing Material Options
    • PVC / CPVC
    • Ryton® (PPS)
    • ABS
    • Epoxy
    • Polycarbonate
    • Kynar® (PVDF)
    • Polyethylene
    • PEEK
    • Teflon™ (PTFE)
    • Ultem® (PEI)
    • Glass
    • Metal
      • Stainless Steel
      • Other Metals Available
  • Thermistor Options
    • PT100 (type A & B)
    • PT1000
    • 10 kohm
    • 30 kohm
    • 100 kohm
    • Any commercially available thermistors and custom options
    • Common temperature accuracy is ±0.3°C and can vary based on thermistor option chosen
  • Reference System
    • Ag / AgCl
    • Differential
    • Custom Options Available
  • Reference Junction Options
    • Double Junction
    • Single Junction
    • Custom Options Available
  • Reference Junction Material / Design
    • Porous Plastic (PTFE / HDPE / PP)
    • Ceramic Pin / Annular / Disc
    • Fiber / Pellon
    • Sleeve Junction / Free Flow (liquid / liquid or ground glass joint)
    • Open Aperture 
    • Solid State
    • Custom Options Available
  • Solution Ground
    • Integrated in Thermowell
    • Integrated in Body Housing
    • Stand-alone
    • Custom Options Available
  • Reference Electrolyte
    • Sealed
      • Soft Gel
      • Solid Gel
    • Refillable
      • Liquid
      • Soft Gel
    • Custom Options Available
  • ORP Sensor Shape 
    • Disc
    • Single Band
    • Double Band
    • Pin
  • ORP Sensor Material
    • Platinum
    • Gold
    • Silver
    • Custom Options Available
  • Integrated Insertions
    • 3/4" NPT
    • 1/2" NPT
    • 1" NPT
    • PG 13.5
    • Custom Options Available
  • Analog
    • Millivolts
    • 4 – 20 mA
    • 0 – 5 V
    • 0 – 10 V
    • Custom Options Available
    • Custom options available with preamp capabilities
  • Digital
    • RS-485 MODBUS RTU
    • Custom Options Available 
  • Connectors
    • Integrated Connectors (detachable or cableless)
      • S7
      • S8
      • Integrated BNC
      • Variopin
      • Custom Options Available 
    • Connectors with Cables (including temperature)
      • BNC
      • DIN
      • MOLEX
      • Mil-spec
      • 2.5 mm / 3.5 mm phono
      • RCA
      • Spade Lugs
      • Tinned Leads
      • LEMO
      • Circular connectors
      • Any commercially available connectors and custom options available