Municipal and industrial wastewater facilities are continuously monitoring water quality upstream for incoming wastewater, on-site at the treatment facility, and downstream to verify effluent treatment is effective. Regulatory requirements dictate that many measurements be taken and reported continuously. AlpHa’s multiparameter sensor & sonde help to monitor multiple water quality parameters simultaneously in wastewater treatment plants. Our sensors streamline maintenance data collection and simplify sensor deployment.

Multiparameter & Sonde in Wastewater Treatment

Parameter Selections

  • pH
  • ORP
  • Reference
  • Conductivity
  • Temperature
  • Dissolved Oxygen
  • Turbidity (wiper included)
  • Ion-Selective Electrode (see table below for range of options)
Ion-Selective ElectrodeRange @ 25°CSensing Element TypeOperating Temp. RangeWarranty
Ammonium (NH4+)0.1 – 14,000 ppm as NPVC Membrane0 – 40°C6 Months
Nitrate (NO3-)0.1 – 14,000 ppm as NPVC Membrane0 – 40°C6 Months
Chloride (Cl-)1.8 – 35,000 ppmSolid State Pellet0 – 80°C12 Months
Fluoride (F-)0.02 – 19,000 ppmSolid State Crystal0 – 80°C12 Months
Calcium (Ca2+)0.5 – 40,100 ppmPVC Membrane0 – 40°C6 Months
Potassium (K+)0.04 – 39,000 ppmPVC Membrane0 – 40°C6 Months
Sulfide (S2-)0.01 – 32,100 ppmSolid State Pellet0 – 80°C12 Months
Sodium (Na+)0.01 – 100,000 ppmSensing Glass0 – 80°C12 Months
Water Hardness (Ca2+/Mg2+)0.5 – 40,000 ppmPVC Membrane0 – 40°C6 Months
Magnesium (Mg2+)0.1 – 30,000 ppmPVC Membrane0 – 40°C6 Months
Bromide (Br-)0.2 – 79,900 ppmSolid State Pellet0 – 80°C12 Months
Cadmium (Cd2+)0.01 – 11,200 ppmSolid State Pellet0 – 80°C12 Months
Copper (Cu2+)0.064 – 6,400 ppmSolid State Pellet0 – 80°C12 Months
Cyanide (CN-)0.2 – 260 ppmSolid State Pellet0 – 80°C12 Months
Iodide (I-)0.01 – 127,000 ppmSolid State Pellet0 – 80°C12 Months
Lead (Pb2+)0.2 – 20,700 ppmSolid State Pellet0 – 80°C12 Months
Silver (Ag+)0.01 – 107,900 ppmSolid State Pellet0 – 80°C12 Months
Fluoroborate (BF4-)VariesPVC Membrane0 – 40°C6 Months
Perchlorate (ClO4-)VariesPVC Membrane0 – 40°C6 Months
Surfactant (X+/X-)VariesPVC Membrane0 – 40°C6 Months
Lithium (Li+)0.2 – 10,000 ppmPVC Membrane0 – 40°C6 Months
  • Form Factor

    • Multiparameter Sensor
      • Up to 5 Parameters (including temperature and reference)
    • Sonde
      • Two Customizable Sizes Available:
        • 7 Parameters (including temperature and reference)
        • 9 Parameters (including temperature and reference)

Communication and Connection Options

  • Analog (multiparameter sensor only)
    • Millivolts
    • Custom options available with preamp capabilities
  • Digital (multiparameter sensor and sonde)
    • RS-485 MODBUS RTU
    • Custom Options Available 
  • Connectors
    • Tinned Leads
    • Spade Lugs
    • DIN
    • MOLEX
    • Mil-spec
    • Circular Connectors
    • Custom Options Available