Drinking water facilities are required to monitor source and process water per regulations set forth by the EPA and comparable regulatory bodies worldwide. Measuring sites include groundwater wells, boreholes, and directly into the source water. Depending on the location of the facility, specific contaminants and parameters must be monitored continuously to ensure proper treatment. AlpHa’s multiparameter sensor & sonde enable drinking water facilities to monitor several parameters in source and process water simultaneously. Thus, improving efficiency, safety, and quality of drinking water treatment systems to ensure that local standards are met.
At AlpHa, our multiparameter & sonde don’t just provide accurate and real-time measurements, they offer several communication and connection options. Hence, they are capable of providing alerts to operators, driving treatment strategies, and maintenance needs.
| Ion-Selective Electrode | Range @ 25°C | Sensing Element Type | Operating Temp. Range | Warranty |
| Ammonium (NH4+) | 0.1 – 14,000 ppm as N | PVC Membrane | 0 – 40°C | 6 Months |
| Nitrate (NO3-) | 0.1 – 14,000 ppm as N | PVC Membrane | 0 – 40°C | 6 Months |
| Chloride (Cl-) | 1.8 – 35,000 ppm | Solid State Pellet | 0 – 80°C | 12 Months |
| Fluoride (F-) | 0.02 – 19,000 ppm | Solid State Crystal | 0 – 80°C | 12 Months |
| Calcium (Ca2+) | 0.5 – 40,100 ppm | PVC Membrane | 0 – 40°C | 6 Months |
| Potassium (K+) | 0.04 – 39,000 ppm | PVC Membrane | 0 – 40°C | 6 Months |
| Sulfide (S2-) | 0.01 – 32,100 ppm | Solid State Pellet | 0 – 80°C | 12 Months |
| Sodium (Na+) | 0.01 – 100,000 ppm | Sensing Glass | 0 – 80°C | 12 Months |
| Water Hardness (Ca2+/Mg2+) | 0.5 – 40,000 ppm | PVC Membrane | 0 – 40°C | 6 Months |
| Magnesium (Mg2+) | 0.1 – 30,000 ppm | PVC Membrane | 0 – 40°C | 6 Months |
| Bromide (Br-) | 0.2 – 79,900 ppm | Solid State Pellet | 0 – 80°C | 12 Months |
| Cadmium (Cd2+) | 0.01 – 11,200 ppm | Solid State Pellet | 0 – 80°C | 12 Months |
| Copper (Cu2+) | 0.064 – 6,400 ppm | Solid State Pellet | 0 – 80°C | 12 Months |
| Cyanide (CN-) | 0.2 – 260 ppm | Solid State Pellet | 0 – 80°C | 12 Months |
| Iodide (I-) | 0.01 – 127,000 ppm | Solid State Pellet | 0 – 80°C | 12 Months |
| Lead (Pb2+) | 0.2 – 20,700 ppm | Solid State Pellet | 0 – 80°C | 12 Months |
| Silver (Ag+) | 0.01 – 107,900 ppm | Solid State Pellet | 0 – 80°C | 12 Months |
| Fluoroborate (BF4-) | Varies | PVC Membrane | 0 – 40°C | 6 Months |
| Perchlorate (ClO4-) | Varies | PVC Membrane | 0 – 40°C | 6 Months |
| Surfactant (X+/X-) | Varies | PVC Membrane | 0 – 40°C | 6 Months |
| Lithium (Li+) | 0.2 – 10,000 ppm | PVC Membrane | 0 – 40°C | 6 Months |