{"id":18162,"date":"2024-11-12T09:00:00","date_gmt":"2024-11-12T09:00:00","guid":{"rendered":"https:\/\/alpha-measure.com\/?p=18162"},"modified":"2024-12-24T17:11:52","modified_gmt":"2024-12-24T17:11:52","slug":"polarographic-vs-galvanic-vs-optical-do-sensor","status":"publish","type":"post","link":"https:\/\/alpha-measure.com\/zh\/polarographic-vs-galvanic-vs-optical-do-sensor\/","title":{"rendered":"Polarographic vs Galvanic vs Optical DO Sensor"},"content":{"rendered":"<p class=\"wp-block-paragraph\">Dissolved oxygen (DO) measurements is critical when it comes to industrial applications, as well as environmental monitoring. There are several sensor technologies utilized for DO measurements, with the most common being polarographic, galvanic, and optical sensors. This article reviews the working principle of each of these sensor types, and also compares features among polarographic vs galvanic vs optical DO sensor.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">What is Dissolved Oxygen<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Dissolved oxygen (DO) is the amount of free, non-compound oxygen that is present in water or any liquid. Utilizing a DO sensor is crucial in the assessment of water quality, pollution control, as well as in the deployment of treatment methods. Generally, sensors interpret <a href=\"https:\/\/alpha-measure.com\/zh\/dissolved-oxygen-measurement\/\">DO measurements<\/a> in two ways, depending on the type. One is DO percent saturation, which refers to the ratio of actual DO content to the maximum possible DO at a specific temperature and pressure. Whereas, DO concentration refers to the actual amount of oxygen in the liquid sample in milligrams per liter (mg\/L), or parts per million (ppm).<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Polarographic DO Sensor<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Polarographic DO sensors consist of a cathode and an anode such as gold and silver, respectively. These are submerged in an electrolyte solution like potassium chloride (KCl), and separated from the sample by an oxygen-permeable membrane.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"360\" height=\"300\" src=\"https:\/\/alpha-measure.com\/wp-content\/uploads\/2024\/10\/Polarographic-DO-Sensor.jpg\" alt=\"polarographic DO sensor\" class=\"wp-image-18164\" srcset=\"https:\/\/alpha-measure.com\/wp-content\/uploads\/2024\/10\/Polarographic-DO-Sensor.jpg 360w, https:\/\/alpha-measure.com\/wp-content\/uploads\/2024\/10\/Polarographic-DO-Sensor-300x250.jpg 300w, https:\/\/alpha-measure.com\/wp-content\/uploads\/2024\/10\/Polarographic-DO-Sensor-14x12.jpg 14w\" sizes=\"(max-width: 360px) 100vw, 360px\" \/><figcaption class=\"wp-element-caption\">\u6709\u793c\u4e86 <a href=\"https:\/\/www.fondriest.com\/environmental-measurements\/measurements\/measuring-water-quality\/dissolved-oxygen-sensors-and-methods\/\">Fondriest<\/a><\/figcaption><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">When the instrument is on, the voltage source applies a small voltage (polarization voltage) between the anode and the cathode. Thus, causing oxygen to diffuse through the membrane and undergo a reduction reaction at the cathode.<\/p>\n\n\n<p class=\"ql-center-displayed-equation\" style=\"line-height: 14px;\"><span class=\"ql-right-eqno\"> &nbsp; <\/span><span class=\"ql-left-eqno\"> &nbsp; <\/span><img decoding=\"async\" src=\"https:\/\/alpha-measure.com\/wp-content\/ql-cache\/quicklatex.com-49fa8b21b27061201db9aa8ead0801c0_l3.png\" height=\"14\" width=\"215\" class=\"ql-img-displayed-equation quicklatex-auto-format\" alt=\"&#92;&#91; &#32;&#79;&#95;&#123;&#50;&#125;&#43;&#50;&#72;&#95;&#123;&#50;&#125;&#79;&#43;&#52;&#101;&#94;&#123;&#45;&#125;&#92;&#114;&#105;&#103;&#104;&#116;&#97;&#114;&#114;&#111;&#119;&#32;&#52;&#79;&#72;&#94;&#123;&#45;&#125; &#92;&#93;\" title=\"\u7531 QuickLaTeX.com \u6e32\u67d3\"\/><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The electrons in the above equation are provided by the oxidation reaction occurring at the anode, and electron flow from anode to cathode represents the measuring signal. This signal is proportional to the partial pressure of oxygen in the solution.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Advantages and Disadvantages of Polarographic DO Sensor<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Polarographic sensors offer several benefits with a few of them as follows:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>High accuracy and precision.<\/li>\n\n\n\n<li>Wide measurement range.<\/li>\n\n\n\n<li>Well-established technology with good track record of reliability.<\/li>\n\n\n\n<li>Suitable for continuous monitoring.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Despite their advantages, polarographic sensors have some drawbacks:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Required warm-up time before use.<\/li>\n\n\n\n<li>Susceptibility to interference from certain gases like hydrogen sulfide, as well as strong acids.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Galvanic DO Sensor<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Galvanic DO sensors operate similarly to polarographic sensors, in that they are both electrochemical sensors. However, galvanic sensors generate their own voltage as dissimilar metals (different electro potentials) serve as the anode and cathode. This intrinsic voltage difference between the two metals eliminates the need for an external power source, as well as warm-up time. Usually, the anode is zinc, lead, or another active metal, while the cathode is silver, or another noble metal. The chemical reaction between oxygen and the anode produces a current proportional to the DO concentration.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full\"><img decoding=\"async\" width=\"360\" height=\"300\" src=\"https:\/\/alpha-measure.com\/wp-content\/uploads\/2024\/10\/Galvanic-DO-Sensor.jpg\" alt=\"Galvanic DO sensor, which is an alternative to polarographic vs optical DO sensors\" class=\"wp-image-18166\" srcset=\"https:\/\/alpha-measure.com\/wp-content\/uploads\/2024\/10\/Galvanic-DO-Sensor.jpg 360w, https:\/\/alpha-measure.com\/wp-content\/uploads\/2024\/10\/Galvanic-DO-Sensor-300x250.jpg 300w, https:\/\/alpha-measure.com\/wp-content\/uploads\/2024\/10\/Galvanic-DO-Sensor-14x12.jpg 14w\" sizes=\"(max-width: 360px) 100vw, 360px\" \/><figcaption class=\"wp-element-caption\">\u6709\u793c\u4e86 <a href=\"https:\/\/www.fondriest.com\/environmental-measurements\/measurements\/measuring-water-quality\/dissolved-oxygen-sensors-and-methods\/\">Fondriest<\/a><\/figcaption><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Galvanic DO Sensor Advantages and Disadvantages<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Galvanic sensors offer several benefits:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Simpler electronics due to self-polarization.<\/li>\n\n\n\n<li>No warm-up time, so can provide immediate response to oxygen changes.<\/li>\n\n\n\n<li>Lower power consumption.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Whereas limitations of this sensor type include:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>A shorter lifespan, in general, vs polarographic sensor due to anode consumption.<\/li>\n\n\n\n<li>Regular membrane and electrolyte replacement required.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">\u5149\u5b66\u6eb6\u89e3\u6c27\u4f20\u611f\u5668<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">An optical DO sensor has a completely different working principle vs its polarographic and galvanic counterparts. It uses a luminescent dye that fluoresces when exposed to a specific wavelength of light. The presence of oxygen quenches this fluorescence, and the sensor measures the change in fluorescence lifetime or intensity to determine the DO concentration.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"510\" height=\"425\" src=\"https:\/\/alpha-measure.com\/wp-content\/uploads\/2024\/10\/Optical-DO-sensor.png\" alt=\"Optical DO sensor, which is an alternative to polarographic vs galvanic\" class=\"wp-image-18168\" srcset=\"https:\/\/alpha-measure.com\/wp-content\/uploads\/2024\/10\/Optical-DO-sensor.png 510w, https:\/\/alpha-measure.com\/wp-content\/uploads\/2024\/10\/Optical-DO-sensor-300x250.png 300w, https:\/\/alpha-measure.com\/wp-content\/uploads\/2024\/10\/Optical-DO-sensor-14x12.png 14w\" sizes=\"(max-width: 510px) 100vw, 510px\" \/><figcaption class=\"wp-element-caption\"><em>\u6709\u793c\u4e86 <\/em><a href=\"https:\/\/www.researchgate.net\/figure\/Cross-section-of-an-optical-DO-sensor_fig2_277012601\"><em>ResearchGate<\/em><\/a><\/figcaption><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\u200bAbove is a typical optical dissolved oxygen (DO) sensor comprised of several key components.\u200b The sensing element contains a luminescent dye that becomes immobilized in a matrix such as sol-gel or xerogel. When the built-in LED emits blue light, the dye reacts to this light. Additionally, some sensors use an LED to emit red light as a reference to enhance accuracy; this red light does not cause luminescence but instead reflects off the dye. The intensity and luminescence lifetime of the dye, when exposed to blue light, are affected by the concentration of dissolved oxygen in the water sample. As oxygen passes through the membrane, it interacts with the dye, which subsequently reduces both the intensity and the lifetime of the luminescence. Finally, a photodetector measures the intensity or lifetime of the returned luminescence, enabling the calculation of dissolved oxygen concentration in the sample.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Advantages and Disadvantages of Optical DO Sensors<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Optical sensors offer numerous benefits including:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Minimal maintenance requirements, so they are ideal for long-term monitoring programs.<\/li>\n\n\n\n<li>Long-term stability with minimal drift, hence minimizing the need for re-calibration.<\/li>\n\n\n\n<li>Flow rate independence, so suitable for harsh environments.<\/li>\n\n\n\n<li>No oxygen consumption during measurements.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Despite these advantages, optical sensors have some drawbacks:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Higher initial cost of optical DO sensor vs polarographic and galvanic counterparts.<\/li>\n\n\n\n<li>Slower response time in comparison to electrochemical sensors.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Differences Between Polarographic vs Galvanic vs Optical DO Sensor<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">All three sensor technologies provide unique features that make one suitable over the other in certain applications. The following table highlights their differences.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Parameter<\/strong><\/td><td><strong>\u6781\u8c31\u5206\u6790<\/strong><\/td><td><strong>\u7535\u9540<\/strong><\/td><td><strong>\u5149\u5b66<\/strong><\/td><\/tr><tr><td>Accuracy and Precision<\/td><td>Provides high accuracy across wide measurement range.<\/td><td>Offers good accuracy for a limited measurement range.<\/td><td>Has the highest accuracy and stability.<\/td><\/tr><tr><td>\u54cd\u5e94\u65f6\u95f4<\/td><td>Moderate response time, suitable where real-time monitoring is not critical.<\/td><td>Fastest response time, beneficial for dynamic environments requiring immediate data.<\/td><td>Fast response time, ideal for applications needing real-time feedback.<\/td><\/tr><tr><td>Maintenance and Calibration<\/td><td>Regular maintenance and frequent calibration needed to ensure accuracy.<\/td><td>Less maintenance and periodic calibration required.<\/td><td>Minimal maintenance and infrequent calibration, hence reducing downtime.<\/td><\/tr><tr><td>Cost Considerations<\/td><td>Generally cost-effective for laboratory and industrial applications.<\/td><td>Affordable and practical cost for portable and field measurements.<\/td><td>Higher initial cost but lower long-term maintenance costs, offering better value for continuous monitoring applications.<\/td><\/tr><tr><td>Application<\/td><td>Suitable for precise measurements in controlled environments.<\/td><td>Ideal for field applications where portability is essential.<\/td><td>Perfect for continuous monitoring in critical applications, since it is less prone to drift.<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">Polarographic vs Galvanic vs Optical DO Sensor<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Advanced DO Sensors from Alpha<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">At Alpha Measurement Solutions, we offer a range of advanced dissolved oxygen sensors that meet the specific needs of different industries. Our offerings include polarographic, galvanic, and optical DO sensors.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Alpha\u2019s Optical Sensor:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u8303\u56f4<\/strong> 0 \u2013 20 ppm (0 \u2013 200% saturation) \/ 0 \u2013 50 ppm (0 \u2013 500% saturation), adjustable within 0 \u2013 50 ppm.<\/li>\n\n\n\n<li><strong>Response Time:<\/strong> T90 &lt; ~35 seconds.<\/li>\n\n\n\n<li><strong>\u51c6\u786e\u6027\uff1a<\/strong> 0 to 10 mg\/L (\u00b11%), 10 to 20 mg\/L (\u00b12%), 20 to 30 mg\/L (\u00b15%), 30 to 50 mg\/L (\u00b115%).<\/li>\n\n\n\n<li><strong>\u6e29\u5ea6\u8303\u56f4\uff1a<\/strong> 0 to 50\u00b0C.<\/li>\n\n\n\n<li><strong>\u538b\u529b\uff1a<\/strong> Operating Atmospheric Pressure: 40 to 115 kPa, Maximum Bearing Pressure: 700 kPa.<\/li>\n\n\n\n<li><strong>\u4fdd\u4fee\uff1a<\/strong> 6 to 24 months depending on the solution.<\/li>\n\n\n\n<li><strong>Features:<\/strong> High stability, minimal drift, and suitable for various environments including biological and hydrocarbon applications.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Alpha\u2019s Polarographic and Galvanic Sensors:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u8303\u56f4<\/strong> 0 \u2013 20 ppm (0 \u2013 200% saturation) \/ 0 \u2013 50 ppm (0 \u2013 500% saturation).<\/li>\n\n\n\n<li><strong>Response Time:<\/strong> T90 &lt; 35 seconds.<\/li>\n\n\n\n<li><strong>\u51c6\u786e\u6027\uff1a<\/strong> \u00b12%.<\/li>\n\n\n\n<li><strong>\u6e29\u5ea6\u8303\u56f4\uff1a<\/strong> 0 \u2013 50\u00b0C continuously monitored, 0 \u2013 80\u00b0C grab sample.<\/li>\n\n\n\n<li><strong>\u538b\u529b\uff1a<\/strong> Operating Atmospheric Pressure: 40 to 115 kPa, Maximum Bearing Pressure: 700 kPa.<\/li>\n\n\n\n<li><strong>\u4fdd\u4fee\uff1a<\/strong> 12 months.<\/li>\n\n\n\n<li><strong>Features:<\/strong> Various polarographic and galvanic configurations, robust design, suitable for diverse applications including process and field measurements.<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>This article reviews the working principle of each of these sensor types, and also compares features among polarographic vs galvanic vs optical DO sensor.<\/p>","protected":false},"author":12,"featured_media":18204,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"inline_featured_image":false,"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_predictive_search_focuskw":"","_ps_exclude_item":"","_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[30],"tags":[],"class_list":["post-18162","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-insights"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.1 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Polarographic vs Galvanic vs Optical DO Sensor - AlpHa Measure<\/title>\n<meta name=\"description\" content=\"This article reviews the working principles of polarographic vs galvanic vs optical DO sensor types, and also compares their features.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/alpha-measure.com\/zh\/polarographic-vs-galvanic-vs-optical-do-sensor\/\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Polarographic vs Galvanic vs Optical DO Sensor\" \/>\n<meta property=\"og:description\" content=\"Dissolved oxygen (DO) measurements is critical when it comes to industrial applications, as well as environmental monitoring. There are several sensor technologies utilized for DO measurements, with the most common being polarographic, galvanic, and optical sensors. This article reviews the working principle of each of these sensor types, and also compares features among polarographic vs galvanic vs optical DO sensor.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/alpha-measure.com\/zh\/polarographic-vs-galvanic-vs-optical-do-sensor\/\" \/>\n<meta property=\"og:site_name\" content=\"AlpHa Measure\" \/>\n<meta property=\"article:published_time\" content=\"2024-11-12T09:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-12-24T17:11:52+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/alpha-measure.com\/wp-content\/uploads\/2024\/11\/Optical-DO-sensor.png\" \/>\n\t<meta property=\"og:image:width\" content=\"510\" \/>\n\t<meta property=\"og:image:height\" content=\"425\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"AlpHa Measurement Solutions\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u4f5c\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"AlpHa Measurement Solutions\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/alpha-measure.com\\\/zh\\\/polarographic-vs-galvanic-vs-optical-do-sensor\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/alpha-measure.com\\\/zh\\\/polarographic-vs-galvanic-vs-optical-do-sensor\\\/\"},\"author\":{\"name\":\"AlpHa Measurement Solutions\",\"@id\":\"https:\\\/\\\/alpha-measure.com\\\/#\\\/schema\\\/person\\\/d40fc86a2532c062070f239738bb2157\"},\"headline\":\"Polarographic vs Galvanic vs Optical DO Sensor\",\"datePublished\":\"2024-11-12T09:00:00+00:00\",\"dateModified\":\"2024-12-24T17:11:52+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/alpha-measure.com\\\/zh\\\/polarographic-vs-galvanic-vs-optical-do-sensor\\\/\"},\"wordCount\":1136,\"publisher\":{\"@id\":\"https:\\\/\\\/alpha-measure.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/alpha-measure.com\\\/zh\\\/polarographic-vs-galvanic-vs-optical-do-sensor\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/alpha-measure.com\\\/wp-content\\\/uploads\\\/2024\\\/11\\\/Optical-DO-sensor.png\",\"articleSection\":[\"Insights\"],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/alpha-measure.com\\\/zh\\\/polarographic-vs-galvanic-vs-optical-do-sensor\\\/\",\"url\":\"https:\\\/\\\/alpha-measure.com\\\/zh\\\/polarographic-vs-galvanic-vs-optical-do-sensor\\\/\",\"name\":\"Polarographic vs Galvanic vs Optical DO Sensor - AlpHa Measure\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/alpha-measure.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/alpha-measure.com\\\/zh\\\/polarographic-vs-galvanic-vs-optical-do-sensor\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/alpha-measure.com\\\/zh\\\/polarographic-vs-galvanic-vs-optical-do-sensor\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/alpha-measure.com\\\/wp-content\\\/uploads\\\/2024\\\/11\\\/Optical-DO-sensor.png\",\"datePublished\":\"2024-11-12T09:00:00+00:00\",\"dateModified\":\"2024-12-24T17:11:52+00:00\",\"description\":\"This article reviews the working principles of polarographic vs galvanic vs optical DO sensor types, and also compares their features.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/alpha-measure.com\\\/zh\\\/polarographic-vs-galvanic-vs-optical-do-sensor\\\/#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/alpha-measure.com\\\/zh\\\/polarographic-vs-galvanic-vs-optical-do-sensor\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/alpha-measure.com\\\/zh\\\/polarographic-vs-galvanic-vs-optical-do-sensor\\\/#primaryimage\",\"url\":\"https:\\\/\\\/alpha-measure.com\\\/wp-content\\\/uploads\\\/2024\\\/11\\\/Optical-DO-sensor.png\",\"contentUrl\":\"https:\\\/\\\/alpha-measure.com\\\/wp-content\\\/uploads\\\/2024\\\/11\\\/Optical-DO-sensor.png\",\"width\":510,\"height\":425},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/alpha-measure.com\\\/zh\\\/polarographic-vs-galvanic-vs-optical-do-sensor\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/alpha-measure.com\\\/zh\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Polarographic vs Galvanic vs Optical DO Sensor\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/alpha-measure.com\\\/#website\",\"url\":\"https:\\\/\\\/alpha-measure.com\\\/\",\"name\":\"AlpHa Measure\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/alpha-measure.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/alpha-measure.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/alpha-measure.com\\\/#organization\",\"name\":\"AlpHa Measure\",\"url\":\"https:\\\/\\\/alpha-measure.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/alpha-measure.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/alpha-measure.com\\\/wp-content\\\/uploads\\\/2022\\\/12\\\/AlpHa-MS-Logo-White_Enpro-small.png\",\"contentUrl\":\"https:\\\/\\\/alpha-measure.com\\\/wp-content\\\/uploads\\\/2022\\\/12\\\/AlpHa-MS-Logo-White_Enpro-small.png\",\"width\":374,\"height\":164,\"caption\":\"AlpHa Measure\"},\"image\":{\"@id\":\"https:\\\/\\\/alpha-measure.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/alpha-measure.com\\\/#\\\/schema\\\/person\\\/d40fc86a2532c062070f239738bb2157\",\"name\":\"AlpHa Measurement Solutions\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8fdc2882f7b267ff673ccf1409c9aec26e3e0f932ffccb57947286cb1e2ce67c?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8fdc2882f7b267ff673ccf1409c9aec26e3e0f932ffccb57947286cb1e2ce67c?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8fdc2882f7b267ff673ccf1409c9aec26e3e0f932ffccb57947286cb1e2ce67c?s=96&d=mm&r=g\",\"caption\":\"AlpHa Measurement Solutions\"},\"url\":\"https:\\\/\\\/alpha-measure.com\\\/zh\\\/author\\\/alpha-measurement\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Polarographic vs Galvanic vs Optical DO Sensor - AlpHa Measure","description":"This article reviews the working principles of polarographic vs galvanic vs optical DO sensor types, and also compares their features.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/alpha-measure.com\/zh\/polarographic-vs-galvanic-vs-optical-do-sensor\/","og_locale":"zh_CN","og_type":"article","og_title":"Polarographic vs Galvanic vs Optical DO Sensor","og_description":"Dissolved oxygen (DO) measurements is critical when it comes to industrial applications, as well as environmental monitoring. There are several sensor technologies utilized for DO measurements, with the most common being polarographic, galvanic, and optical sensors. This article reviews the working principle of each of these sensor types, and also compares features among polarographic vs galvanic vs optical DO sensor.","og_url":"https:\/\/alpha-measure.com\/zh\/polarographic-vs-galvanic-vs-optical-do-sensor\/","og_site_name":"AlpHa Measure","article_published_time":"2024-11-12T09:00:00+00:00","article_modified_time":"2024-12-24T17:11:52+00:00","og_image":[{"width":510,"height":425,"url":"https:\/\/alpha-measure.com\/wp-content\/uploads\/2024\/11\/Optical-DO-sensor.png","type":"image\/png"}],"author":"AlpHa Measurement Solutions","twitter_card":"summary_large_image","twitter_misc":{"\u4f5c\u8005":"AlpHa Measurement Solutions","\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"6 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/alpha-measure.com\/zh\/polarographic-vs-galvanic-vs-optical-do-sensor\/#article","isPartOf":{"@id":"https:\/\/alpha-measure.com\/zh\/polarographic-vs-galvanic-vs-optical-do-sensor\/"},"author":{"name":"AlpHa Measurement Solutions","@id":"https:\/\/alpha-measure.com\/#\/schema\/person\/d40fc86a2532c062070f239738bb2157"},"headline":"Polarographic vs Galvanic vs Optical DO Sensor","datePublished":"2024-11-12T09:00:00+00:00","dateModified":"2024-12-24T17:11:52+00:00","mainEntityOfPage":{"@id":"https:\/\/alpha-measure.com\/zh\/polarographic-vs-galvanic-vs-optical-do-sensor\/"},"wordCount":1136,"publisher":{"@id":"https:\/\/alpha-measure.com\/#organization"},"image":{"@id":"https:\/\/alpha-measure.com\/zh\/polarographic-vs-galvanic-vs-optical-do-sensor\/#primaryimage"},"thumbnailUrl":"https:\/\/alpha-measure.com\/wp-content\/uploads\/2024\/11\/Optical-DO-sensor.png","articleSection":["Insights"],"inLanguage":"zh-Hans"},{"@type":"WebPage","@id":"https:\/\/alpha-measure.com\/zh\/polarographic-vs-galvanic-vs-optical-do-sensor\/","url":"https:\/\/alpha-measure.com\/zh\/polarographic-vs-galvanic-vs-optical-do-sensor\/","name":"Polarographic vs Galvanic vs Optical DO Sensor - AlpHa Measure","isPartOf":{"@id":"https:\/\/alpha-measure.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/alpha-measure.com\/zh\/polarographic-vs-galvanic-vs-optical-do-sensor\/#primaryimage"},"image":{"@id":"https:\/\/alpha-measure.com\/zh\/polarographic-vs-galvanic-vs-optical-do-sensor\/#primaryimage"},"thumbnailUrl":"https:\/\/alpha-measure.com\/wp-content\/uploads\/2024\/11\/Optical-DO-sensor.png","datePublished":"2024-11-12T09:00:00+00:00","dateModified":"2024-12-24T17:11:52+00:00","description":"This article reviews the working principles of polarographic vs galvanic vs optical DO sensor types, and also compares their features.","breadcrumb":{"@id":"https:\/\/alpha-measure.com\/zh\/polarographic-vs-galvanic-vs-optical-do-sensor\/#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/alpha-measure.com\/zh\/polarographic-vs-galvanic-vs-optical-do-sensor\/"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/alpha-measure.com\/zh\/polarographic-vs-galvanic-vs-optical-do-sensor\/#primaryimage","url":"https:\/\/alpha-measure.com\/wp-content\/uploads\/2024\/11\/Optical-DO-sensor.png","contentUrl":"https:\/\/alpha-measure.com\/wp-content\/uploads\/2024\/11\/Optical-DO-sensor.png","width":510,"height":425},{"@type":"BreadcrumbList","@id":"https:\/\/alpha-measure.com\/zh\/polarographic-vs-galvanic-vs-optical-do-sensor\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/alpha-measure.com\/zh\/"},{"@type":"ListItem","position":2,"name":"Polarographic vs Galvanic vs Optical DO Sensor"}]},{"@type":"WebSite","@id":"https:\/\/alpha-measure.com\/#website","url":"https:\/\/alpha-measure.com\/","name":"AlpHa Measure","description":"","publisher":{"@id":"https:\/\/alpha-measure.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/alpha-measure.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/alpha-measure.com\/#organization","name":"AlpHa Measure","url":"https:\/\/alpha-measure.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/alpha-measure.com\/#\/schema\/logo\/image\/","url":"https:\/\/alpha-measure.com\/wp-content\/uploads\/2022\/12\/AlpHa-MS-Logo-White_Enpro-small.png","contentUrl":"https:\/\/alpha-measure.com\/wp-content\/uploads\/2022\/12\/AlpHa-MS-Logo-White_Enpro-small.png","width":374,"height":164,"caption":"AlpHa Measure"},"image":{"@id":"https:\/\/alpha-measure.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/alpha-measure.com\/#\/schema\/person\/d40fc86a2532c062070f239738bb2157","name":"AlpHa \u6d4b\u91cf\u89e3\u51b3\u65b9\u6848","image":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/secure.gravatar.com\/avatar\/8fdc2882f7b267ff673ccf1409c9aec26e3e0f932ffccb57947286cb1e2ce67c?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/8fdc2882f7b267ff673ccf1409c9aec26e3e0f932ffccb57947286cb1e2ce67c?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8fdc2882f7b267ff673ccf1409c9aec26e3e0f932ffccb57947286cb1e2ce67c?s=96&d=mm&r=g","caption":"AlpHa Measurement Solutions"},"url":"https:\/\/alpha-measure.com\/zh\/author\/alpha-measurement\/"}]}},"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/alpha-measure.com\/wp-content\/uploads\/2024\/11\/Optical-DO-sensor.png","_links":{"self":[{"href":"https:\/\/alpha-measure.com\/zh\/wp-json\/wp\/v2\/posts\/18162","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/alpha-measure.com\/zh\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/alpha-measure.com\/zh\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/alpha-measure.com\/zh\/wp-json\/wp\/v2\/users\/12"}],"replies":[{"embeddable":true,"href":"https:\/\/alpha-measure.com\/zh\/wp-json\/wp\/v2\/comments?post=18162"}],"version-history":[{"count":19,"href":"https:\/\/alpha-measure.com\/zh\/wp-json\/wp\/v2\/posts\/18162\/revisions"}],"predecessor-version":[{"id":18205,"href":"https:\/\/alpha-measure.com\/zh\/wp-json\/wp\/v2\/posts\/18162\/revisions\/18205"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/alpha-measure.com\/zh\/wp-json\/wp\/v2\/media\/18204"}],"wp:attachment":[{"href":"https:\/\/alpha-measure.com\/zh\/wp-json\/wp\/v2\/media?parent=18162"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/alpha-measure.com\/zh\/wp-json\/wp\/v2\/categories?post=18162"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/alpha-measure.com\/zh\/wp-json\/wp\/v2\/tags?post=18162"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}