{"id":14327,"date":"2023-10-25T16:02:47","date_gmt":"2023-10-25T16:02:47","guid":{"rendered":"https:\/\/alphameasure.flywheelsites.com\/?p=14327"},"modified":"2025-03-26T15:52:50","modified_gmt":"2025-03-26T15:52:50","slug":"reference-electrode-nature-and-role-124","status":"publish","type":"post","link":"https:\/\/alpha-measure.com\/zh\/reference-electrode-nature-and-role-124\/","title":{"rendered":"\u53c2\u6bd4\u7535\u6781\uff1a\u6027\u8d28\u548c\u4f5c\u7528"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"14327\" class=\"elementor elementor-14327\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-3a923f7f elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"3a923f7f\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-c1a18c2\" data-id=\"c1a18c2\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-6de13223 elementor-widget elementor-widget-text-editor\" data-id=\"6de13223\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\n<p class=\"wp-block-paragraph\">This article aims to educate the user about one of the most important aspects of electrode measurements &#8211; Reference Electrodes.\u00a0They are the source of most difficulties you encounter while performing measurements, and more specifically, the reference electrode&#8217;s liquid junction.\u00a0<\/p>\n\n<p class=\"wp-block-paragraph\">Therefore, a greater knowledge of the role that the reference electrode plays is of great benefit to the user.\u00a0 We will discuss the various types of reference electrodes as well as the components which make them up. In addition, we will review their relative strengths and weaknesses to facilitate choosing a suitable reference electrode for your application.<\/p>\n<h2>Why is a Reference Electrode Important<\/h2>\n\n<p class=\"wp-block-paragraph\">The purpose of a reference electrode is to complete the electrical circuit and also provide a stable ground voltage to carry out electrochemical measurements. It achieves this by providing an isolated and stable chemical reaction, thus, producing a predictable voltage value. Effectiveness of a reference electrode is in its ability to produce a stable as well as reproducible potential for comparison with the indicating electrode potential.<\/p>\n\n<h2 class=\"wp-block-heading\">Construction of a Reference Electrode<\/h2>\n\n<p class=\"wp-block-paragraph\">The typical reference electrode consists of an internal element, normally silver-silver chloride, surrounded by an electrolyte-containing filling solution. Generally, this solution is KCl, saturated with AgCl, inside a glass or plastic body salt bridge, and terminating at the liquid junction.<\/p>\n\n<p class=\"wp-block-paragraph\">It is important that the internal element remains wet and surrounded by the reference electrolyte-filling solution.\u00a0 Because of this, VLC ships all its reference electrodes pre-filled with reference filling solution.\u00a0 Moreover, sealing the fill hole with tape or rubber grommet is necessary to prevent leakage of the solution during shipment. Also, removing the seal prior to use is mandatory. Else, as the fill solution leaks out of the liquid junction, there will be a vacuum inside the electrode. This will progress until the fill solution can no longer flow out of the electrode. Thus, leading to drifting or instability of readings.<\/p>\n\n<p class=\"wp-block-paragraph\">Shipping our reference electrodes is usually with a cap containing reference fill solution covering the liquid junction.\u00a0 Like the internal element, it is necessary to keep the liquid junction wet, because this helps the electrode to function properly.<\/p>\n\n<h2 class=\"wp-block-heading\">Liquid Junctions of a Reference Electrode<\/h2>\n\n<p class=\"wp-block-paragraph\">The liquid junction allows the leakage of reference electrolyte filling solution into the sample. As a result, it completes the electrical circuit needed for potentiometric measurements.\u00a0 VLC can manufacture reference electrodes in various configurations and from various materials. Also, there are a variety of liquid junction styles and materials to choose from. However, keep in mind that there is no &#8220;universal&#8221; liquid junction. The difference between the various junction types is mainly the potential that each liquid junction-sample interface generates. Another difference is the flow rate of the reference filling solution through the liquid junction into the sample.\u00a0\u00a0The choice of liquid junction type is mostly application dependent.<\/p>\n\n<p class=\"wp-block-paragraph\">There are two basic\u00a0classes of liquid junctions.\u00a0 The first is a &#8220;flowing&#8221;\u00a0junction.\u00a0 This class of liquid junction allows the electrolyte in its entirety (liquid\/gel and all) to make contact with the sample\u00a0through the junction (see Glass Sleeve and Open Aperture examples below). \u00a0Liquid junctions\u00a0of this type have\u00a0moderate to high flow rates. Also, they provide low resistance and low junction potentials, but have a higher degree of sample contamination.\u00a0<\/p>\n\n<p class=\"wp-block-paragraph\">The second class of liquid junctions is a &#8220;Diffusion&#8221; junction (see Annular Ceramic, Ceramic Wick, and also Teflon examples below).\u00a0 This class allows only the ions of the electrolyte to pass through the junction and into the test sample. Diffusion-type liquid junctions exhibit lower flow rates and less sample contamination but easily clog. The table in the next section describes the various reference liquid junctions Alpha offers and also other key details.<\/p>\n\n<h3 class=\"wp-block-heading\">Reference Liquid Junction Offerings from Alpha<\/h3>\n\n<figure class=\"wp-block-table has-small-font-size\">\n<table>\n<tbody>\n<tr>\n<td><strong>Alpha Liquid Junction<\/strong><\/td>\n<td><strong>Diagram<\/strong><\/td>\n<td><strong>Description<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Annular Ceramic<\/td>\n<td><img decoding=\"async\" class=\"alignnone wp-image-1538 size-full\" src=\"https:\/\/alpha-measure.com\/wp-content\/uploads\/2023\/01\/AnnularCeramic-LJ-1.png\" alt=\"Annular Ceramic Junction Type of Reference Electrode\" width=\"133\" height=\"231\" \/><\/td>\n<td>Making an annular ceramic junction involves wedging a thin layer of ceramic between the outer body and inner body of the reference chamber.\u00a0 The ceramic itself has a small pore size, therefore, it exhibits a low flow rate, extending the time between refilling of the reference electrolyte. This type of liquid junction are suitable for most general laboratory-type applications. However, the principle drawback of this style is that the liquid junction itself is difficult to clean on contamination. Nevertheless, careful selection of the reference electrolyte can help reduce\/eliminate the fouling effect.<\/td>\n<\/tr>\n<tr>\n<td>Ceramic Wick<\/td>\n<td><img decoding=\"async\" class=\"alignnone wp-image-1539 size-full\" src=\"https:\/\/alpha-measure.com\/wp-content\/uploads\/2023\/01\/ceramic-wick-LJ-1.png\" alt=\"Ceramic Wick Junction Type of Reference Electrode\" width=\"164\" height=\"260\" \/><\/td>\n<td>A ceramic wick junction entails inserting a ceramic wick (also called a frit) through the tip\/end of the reference chamber.\u00a0 Also, it shares many characteristics with the annular ceramic-style liquid junction.\u00a0 It has a small pore size (although various pore sizes are available upon special request), and therefore, a slow flow rate.\u00a0 In addition, this liquid junction type is difficult to clean.\u00a0 Again, careful selection of the reference electrolyte can help mitigate\/eliminate the fouling effect.<\/td>\n<\/tr>\n<tr>\n<td>P.T.F.E. (Teflon)<\/td>\n<td><img decoding=\"async\" class=\"alignnone wp-image-1542 size-full\" src=\"https:\/\/alpha-measure.com\/wp-content\/uploads\/2023\/01\/PTFE-LJ.png\" alt=\"Teflon junction type of reference electrode\" width=\"170\" height=\"260\" \/><\/td>\n<td>Making this liquid junction involves press-fitting a plug of Teflon into the tip of the reference electrode.\u00a0 Teflon is a very versatile liquid junction material, because it can serve in either a flowing reference design (with a liquid reference electrolyte, such as in laboratory-style electrodes), or in a diffusion-style liquid junction (with a gelled electrolyte).\u00a0\u00a0This type of liquid junction is common in industrial application electrodes.\u00a0 When combined with a polymer gel reference electrolyte, the hydrophobic nature of Teflon helps prevent contamination of the liquid junction. While its large pore size makes for low junction potentials, and the ability to more rapidly equilibrate to pressure changes in those applications where the environment is dynamic in nature.<\/td>\n<\/tr>\n<tr>\n<td>Glass Sleeve<\/td>\n<td><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1540\" src=\"https:\/\/alpha-measure.com\/wp-content\/uploads\/2023\/01\/GlassSleeve-LJ-1.png\" alt=\"\" width=\"160\" height=\"260\" \/><\/td>\n<td>This liquid junction type is made by drilling a small hole in the side of the reference electrode.\u00a0 A movable, tapered ground glass &#8220;sleeve&#8221; envelopes the outer body of the reference electrode.\u00a0 This sleeve can be moved up the electrode body to fully expose the hole, thus, allowing quick draining of the reference electrolyte for cleaning, and moved down to cover the hole for operational use.\u00a0 This style of liquid junction exhibits an extremely high flow rate. Therefore, it offers highly stable and very low junction potentials.\u00a0 The very fast flow rate of these types of reference electrodes requires frequent refilling of the reference electrolyte, as a result, sample contamination may be of concern for certain applications.\u00a0 Generally, this style of reference electrodes is common in laboratory applications, where accuracy is paramount.<\/td>\n<\/tr>\n<tr>\n<td>\u6253\u5f00\u5149\u5708<\/td>\n<td><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1541\" src=\"https:\/\/alpha-measure.com\/wp-content\/uploads\/2023\/01\/OpenAperture-LJ.png\" alt=\"\" width=\"163\" height=\"260\" \/><\/td>\n<td>This liquid junction is made by simply drilling a hole in the side of the reference electrode.\u00a0 In addition, its reference electrolyte must be gelled in some fashion to prevent overly rapid depletion of the reference electrolyte.\u00a0 This gel is completely exposed to the sample.\u00a0 The open aperture style liquid junction is common in applications having high solids content as well as in suspensions\/emulsions. Moreover, it is beneficial in the monitoring of precipitation reactions, which can easily clog\/foul other liquid junction styles which have a physical, porous salt bridge.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<figcaption class=\"wp-element-caption\">Liquid Junctions Offerings from Alpha<\/figcaption>\n<\/figure>\n\n<h2 class=\"wp-block-heading\"><b>Contamination Effects on a Reference Electrode<\/b><\/h2>\n\n<p class=\"wp-block-paragraph\">As stated earlier, the Silver-Silver chloride reference element is the reference element of choice. This goes with a potassium chloride solution saturated with Silver chloride used as the reference electrolyte fill.\u00a0Moreover, the KCl solution is saturated with AgCl. Thus, preventing incidental stripping of the AgCl from the Silver wire (the reference internal element)\u00a0to dissolve into the KCl reference electrolyte solution.<\/p>\n\n<p class=\"wp-block-paragraph\">But what do we do if the sample we wish to test would become contaminated by contacting Silver ions? For example, in the food industry.\u00a0Or what if the sample contains silver ions, and we want to avoid exposure to a reference electrolyte containing chloride ions?<\/p>\n\n<figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"214\" height=\"341\" class=\"wp-image-7928\" src=\"https:\/\/alpha-measure.com\/wp-content\/uploads\/2023\/09\/Double-Junction-Reference-Electrode.png\" alt=\"Double Junction Reference Electrode\" srcset=\"https:\/\/alpha-measure.com\/wp-content\/uploads\/2023\/09\/Double-Junction-Reference-Electrode.png 214w, https:\/\/alpha-measure.com\/wp-content\/uploads\/2023\/09\/Double-Junction-Reference-Electrode-188x300.png 188w\" sizes=\"(max-width: 214px) 100vw, 214px\" \/>\n<figcaption class=\"wp-element-caption\"><em><strong>Double Junction Reference Electrode<\/strong><\/em><\/figcaption>\n<\/figure>\n\n<p class=\"wp-block-paragraph\">Solving this problem entails adding a second salt bridge, or junction to the reference electrode. Hence, insulating the inner Silver-Silver chloride reference element from the sample.\u00a0 This secondary salt bridge can then be filled with a reference electrolyte solution, which does not contain a contaminant to the sample. For a sample containing silver ions, one might choose a saturated Potassium nitrate (KNO<sub>3<\/sub>) solution\u00a0as the reference <a href=\"https:\/\/alpha-measure.com\/zh\/non-electrolyte-vs-electrolyte-solutions\/\" target=\"_blank\" rel=\"noreferrer noopener\">electrolyte<\/a>.<\/p>\n\n<h2 class=\"wp-block-heading\"><b>Side Arm Reference with Fill Solution Reservoir<\/b><\/h2>\n\n<p class=\"wp-block-paragraph\">Contamination of the internal reference element by the sample is also possible. This occurs if the level of the reference electrode&#8217;s filling solution is not properly maintained. The desired flow of filling solution from the reference chamber into the sample is only possible if there is a positive head pressure. Meaning that the level of filling solution must be higher than that of the sample.\u00a0 If the sample level is higher than that of the level of the reference filling solution, then the normal direction of flow can reverse. Therefore, making the sample flow into the reference chamber.\u00a0<\/p>\n\n<p class=\"wp-block-paragraph\">At the minimum, this can result in the formation of unstable potentials. Also, extended sample exposure to the internal reference element can lead to contamination\/fouling of the internal reference element.\u00a0 If this happens, then the reference electrode must be replaced. Because of this, VLC offers reference electrodes with a built-in sidearm, that maintains positive head pressure requirements for proper functioning. The image below shows how one can connect a reservoir, filled with reference electrolyte filling solution, to the reference electrode, thus, maintaining positive head pressure. This setup is common in long-term measurements applications, if daily electrode maintenance is not possible or convenient.<\/p>\n\n<figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"135\" height=\"343\" class=\"wp-image-7935\" src=\"https:\/\/alpha-measure.com\/wp-content\/uploads\/2023\/09\/Reservoir.png\" alt=\"How to connect reference electrodes to reservoir.\" srcset=\"https:\/\/alpha-measure.com\/wp-content\/uploads\/2023\/09\/Reservoir.png 135w, https:\/\/alpha-measure.com\/wp-content\/uploads\/2023\/09\/Reservoir-118x300.png 118w\" sizes=\"(max-width: 135px) 100vw, 135px\" \/>\n<figcaption class=\"wp-element-caption\"><em><strong>Electrode to Reservoir Connection<\/strong><\/em><\/figcaption>\n<\/figure>\n\n<h2 class=\"wp-block-heading\"><b>Liquid Junction Potentials of Reference Electrodes<\/b><\/h2>\n\n<p class=\"wp-block-paragraph\">When a reference electrode is in a sample, a potential develops at the junction of the reference filling solution and sample. This is the liquid junction potential. It develops because of the difference in composition between the reference fill solution and the sample.\u00a0 The liquid junction design allows the interdiffusion of ions between the reference filling solution and the sample.\u00a0\u00a0However, different ions diffuse at varying rates, so the electrical charge they carry will move unequally across the junction.\u00a0 Hence, the formation of the reference junction potential.\u00a0 We can control the magnitude and also stability of this potential by careful selecting the liquid junction material and filling solution.<\/p>\n\n<p class=\"wp-block-paragraph\">The table of liquid junction offerings from Alpha serves as a guide as to which junction material type is appropriate for your application.\u00a0 The next section will discuss in more detail our choice of reference fill solution.<\/p>\n\n<h2 class=\"wp-block-heading\"><b>Reference Electrode Filling Solutions<\/b><\/h2>\n\n<p class=\"wp-block-paragraph\">The ideal reference-filling solution for any particular application should meet the following requirements:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>The filling solution&#8217;s electrolyte should neither react with nor contaminate the sample.<\/li>\n\n<li>The filling solution should provide the dominant ions (in concentration) present at the liquid junction interface.<\/li>\n\n<li>The diffusion rates of the cations as well as anions of the filling solution&#8217;s electrolyte should be as close as possible.<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">We have already mentioned an example of the 1st requirement &#8211; the typical reference filling solution of KCl reacting with a sample containing Silver to form silver chloride.\u00a0 The second requirement is readily accomplished by simply making the fill solution either saturated or sufficiently concentrated with the electrolyte of choice.\u00a0 The third requirement requires choosing a reference fill solution whose electrolyte provides equal transference of the positive and also the negative charges moving across the liquid junction.<\/p>\n\n<p class=\"wp-block-paragraph\">The ability of an ion to carry an electrical charge is related to its ionic equivalent conductance (\u03bb<sup>0<\/sup>, mho-cm\/equivalent\/liter).\u00a0 Below is a table of varying ions as well as their equivalent conductance in various solutions.<\/p>\n\n<h3 class=\"wp-block-heading has-text-align-center has-medium-font-size\"><strong>Limiting Equivalent Conductance<\/strong><\/h3>\n\n<figure class=\"wp-block-table\">\n<table>\n<tbody>\n<tr>\n<td><strong>Cations<\/strong><\/td>\n<td><strong>Aqueous<\/strong><\/td>\n<td><strong>Methanol<\/strong><\/td>\n<td><strong>Ethanol<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Ag<sup>+<\/sup><\/td>\n<td>61.9<\/td>\n<td>&#8212;<\/td>\n<td>17.9<\/td>\n<\/tr>\n<tr>\n<td>Ba<sup>+2<\/sup><\/td>\n<td>63.6<\/td>\n<td>62.0<\/td>\n<td>&#8212;<\/td>\n<\/tr>\n<tr>\n<td>Ca<sup>+2<\/sup><\/td>\n<td>59.5<\/td>\n<td>61.0<\/td>\n<td>&#8212;<\/td>\n<\/tr>\n<tr>\n<td>Cu<sup>+2<\/sup><\/td>\n<td>53.6<\/td>\n<td>&#8212;<\/td>\n<td>&#8212;<\/td>\n<\/tr>\n<tr>\n<td>H<sup>+<\/sup><\/td>\n<td>349.8<\/td>\n<td>141.8<\/td>\n<td>57.4<\/td>\n<\/tr>\n<tr>\n<td>K<sup>+<\/sup><\/td>\n<td>73.5<\/td>\n<td>52.4<\/td>\n<td>22.0<\/td>\n<\/tr>\n<tr>\n<td>Li<sup>+<\/sup><\/td>\n<td>38.7<\/td>\n<td>39.8<\/td>\n<td>15.0<\/td>\n<\/tr>\n<tr>\n<td>Mg<sup>+2<\/sup><\/td>\n<td>53.1<\/td>\n<td>59.0<\/td>\n<td>&#8212;<\/td>\n<\/tr>\n<tr>\n<td>Na<sup>+2<\/sup><\/td>\n<td>50.1<\/td>\n<td>45.9<\/td>\n<td>18.9<\/td>\n<\/tr>\n<tr>\n<td>NH<sub>4<\/sub><sup>+<\/sup><\/td>\n<td>73.5<\/td>\n<td>57.9<\/td>\n<td>19.6<\/td>\n<\/tr>\n<tr>\n<td>(CH<sub>3<\/sub>)<sub>4<\/sub>N<sup>+<\/sup><\/td>\n<td>44.9<\/td>\n<td>70.1<\/td>\n<td>28.3<\/td>\n<\/tr>\n<tr>\n<td>(C<sub>2<\/sub>H<sub>5<\/sub>)(CH<sub>3<\/sub>)<sub>3<\/sub>N<sup>+<\/sup><\/td>\n<td>40.8<\/td>\n<td>&#8212;<\/td>\n<td>&#8212;<\/td>\n<\/tr>\n<tr>\n<td>(C<sub>4<\/sub>Hg)(CH<sub>3<\/sub>)<sub>3<\/sub>N<sup>+<\/sup><\/td>\n<td>33.6<\/td>\n<td>&#8212;<\/td>\n<td>&#8212;<\/td>\n<\/tr>\n<tr>\n<td>(C<sub>2<\/sub>H<sub>5<\/sub>)<sub>4<\/sub>N<sup>+<\/sup><\/td>\n<td>32.7<\/td>\n<td>60.4<\/td>\n<td>27.8<\/td>\n<\/tr>\n<tr>\n<td>(C<sub>3<\/sub>H<sub>7<\/sub>)<sub>4<\/sub>N<sup>+<\/sup><\/td>\n<td>23.4<\/td>\n<td>46.1<\/td>\n<td>&#8212;<\/td>\n<\/tr>\n<tr>\n<td>(<i>n<\/i>-C<sub>4<\/sub>H<sub>9<\/sub>)<sub>4<\/sub>N<sup>+<\/sup><\/td>\n<td>19.5<\/td>\n<td>39.1<\/td>\n<td>&#8212;<\/td>\n<\/tr>\n<tr>\n<td>Anions<\/td>\n<\/tr>\n<tr>\n<td>Br<sup>&#8211;<\/sup><\/td>\n<td>78.14<\/td>\n<td>56.4<\/td>\n<td>26.0<\/td>\n<\/tr>\n<tr>\n<td>Cl<sup>&#8211;<\/sup><\/td>\n<td>76.4<\/td>\n<td>51.2<\/td>\n<td>24.3<\/td>\n<\/tr>\n<tr>\n<td>CO<sub>3<\/sub><sup>-2<\/sup><\/td>\n<td>69.3<\/td>\n<td>&#8212;<\/td>\n<td>&#8212;<\/td>\n<\/tr>\n<tr>\n<td>ClO<sub>4<\/sub><sup>&#8211;<\/sup><\/td>\n<td>67.3<\/td>\n<td>70.1<\/td>\n<td>33.5<\/td>\n<\/tr>\n<tr>\n<td>F<sup>&#8211;<\/sup><\/td>\n<td>55.4<\/td>\n<td>&#8212;<\/td>\n<td>&#8212;<\/td>\n<\/tr>\n<tr>\n<td>HCO<sub>3<\/sub><sup>&#8211;<\/sup><\/td>\n<td>44.5<\/td>\n<td>&#8212;<\/td>\n<td>&#8212;<\/td>\n<\/tr>\n<tr>\n<td>I<sup>&#8211;<\/sup><\/td>\n<td>76.8<\/td>\n<td>62.7<\/td>\n<td>28.8<\/td>\n<\/tr>\n<tr>\n<td>NO<sub>3<\/sub><sup>&#8211;<\/sup><\/td>\n<td>71.4<\/td>\n<td>60.5<\/td>\n<td>28.0<\/td>\n<\/tr>\n<tr>\n<td>OH<sup>&#8211;<\/sup><\/td>\n<td>198.6<\/td>\n<td>&#8212;<\/td>\n<td>&#8212;<\/td>\n<\/tr>\n<tr>\n<td>SO<sub>4<\/sub><sup>-2<\/sup><\/td>\n<td>80.0<\/td>\n<td>&#8212;<\/td>\n<td>&#8212;<\/td>\n<\/tr>\n<tr>\n<td>SCN<sup>&#8211;<\/sup><\/td>\n<td>66.0<\/td>\n<td>60.8<\/td>\n<td>29.7<\/td>\n<\/tr>\n<tr>\n<td>Acetate<sup>&#8211;<\/sup><\/td>\n<td>40.9<\/td>\n<td>53.0<\/td>\n<td>&#8212;<\/td>\n<\/tr>\n<tr>\n<td>Benzoate<sup>&#8211;<\/sup><\/td>\n<td>32.4<\/td>\n<td>\u00a0<\/td>\n<td>\u00a0<\/td>\n<\/tr>\n<tr>\n<td><i>N<\/i>-Butyrate<sup>&#8211;<\/sup><\/td>\n<td>32.6<\/td>\n<td>\u00a0<\/td>\n<td>\u00a0<\/td>\n<\/tr>\n<tr>\n<td>Oxalate<sup>-2<\/sup><\/td>\n<td>74.2<\/td>\n<td>\u00a0<\/td>\n<td>\u00a0<\/td>\n<\/tr>\n<tr>\n<td>Picrate<sup>&#8211;<\/sup><\/td>\n<td>30.4<\/td>\n<td>47.0<\/td>\n<td>26.3<\/td>\n<\/tr>\n<tr>\n<td>Propionte<sup>&#8211;<\/sup><\/td>\n<td>35.8<\/td>\n<td>&#8212;<\/td>\n<td>21.0<\/td>\n<\/tr>\n<tr>\n<td>* From Parsons, &#8220;Handbook of Electrochemical Constants,&#8221; Butterworth, London, 1959, and L. Meites, &#8220;Handbook of Analytical Chemistry,&#8221; McGraw-Hill, New York, 1973.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<figcaption class=\"wp-element-caption\">Limiting Equivalent Conductance of Ions<\/figcaption>\n<\/figure>\n\n<p class=\"wp-block-paragraph\">Looking at this table, one can see why KCl is a very popular reference electrolyte fill solution.\u00a0 Potassium has a limiting equivalent conductance of 73.5, while Chloride has a limiting\u00a0equivalent conductance of 76.4.\u00a0 Take note of the limiting equivalent conductance values for H<sup>+<\/sup> and also OH<sup>&#8211;<\/sup>.\u00a0 They are much higher than the values for most other ions.\u00a0 This is what makes achieving equitransference difficult in strong acids as well as in strong bases. Making it often the cause for the long response times encountered when measuring these samples.<\/p>\n\n<h2 class=\"wp-block-heading\"><b>Effects of Changing the Reference Electrode Fill Solution<\/b><\/h2>\n\n<p class=\"wp-block-paragraph\">After changing a reference electrode&#8217;s filling solution, the potential at the fill solution-internal reference element interface changes as well.\u00a0 This new potential may be less stable and\/or more sensitive to temperature changes than the previous fill solution. So, it is important to take note of response times when using a new reference fill solution.\u00a0 Also, this new potential takes time to establish itself, so it is good practice to allow the setup stand overnight. Because of this, most people do not change out the reference fill solution. Rather, they simply purchase separate reference electrodes, with each reference electrode having a single reference fill solution.<\/p>\n\n<h2 class=\"wp-block-heading\">Crystallization of Reference Electrodes<\/h2>\n\n<p class=\"wp-block-paragraph\">Regular users of reference electrodes often encounter the formation of crystals at the bottom end of their electrodes. Moreover, these are simply the salt crystals of the electrolyte solution of the reference electrode.\u00a0 To novice users, however, this at first may seem to be some form of contamination, but it is not.\u00a0 Most reference electrolyte filling solutions are saturated salt solutions.\u00a0 Due to reasons such as water evaporating from the fill solution or temperature drop, these salts fall out of the solution. Then, they form crystals, which naturally settles to the bottom of the electrode.\u00a0 These salt crystals will not, up to a point, interfere with the electrode&#8217;s performance.\u00a0 The crystals, actually serve a purpose to us, because they ensure the filling solution maintains saturation.\u00a0<\/p>\n\n<p class=\"wp-block-paragraph\">However, over time, these crystals can become packed together tightly and obstruct the flow of reference-filling solution through the junction.\u00a0 Resolving this involves draining the reference electrode of its reference fill solution and also refilling it with distilled water.\u00a0 This allows the salt crystals to dissolve into the distilled water, before putting in a new reference filling solution.\u00a0 Note, sometimes, rinsing several times with distilled water may be necessary to dissolve all the crystals.<\/p>\n\n<h2 class=\"wp-block-heading\"><b>Cleaning\/Unclogging a Liquid Junction<\/b><\/h2>\n\n<p class=\"wp-block-paragraph\">Your liquid junction likely needs unclogging if readings are drifty, jumpy, or require a long stabilization time.\u00a0 The first cleaning method to try is the same as that in the crystallization section above.\u00a0 Simply drain the electrode of the fill solution, rinse it several times with distilled water, and then refill the filling solution.\u00a0 If this doesn&#8217;t improve the performance of the electrode, then you can next try pulling a vacuum over the liquid junction (typically located at the tip of the electrode) to try and force the filling solution through the liquid junction.\u00a0 If your liquid junction still needs unclogging, then it is necessary to take more severe steps.\u00a0<\/p>\n\n<p class=\"wp-block-paragraph\">The next step is to boil the liquid junction in a dilute KCl solution for 10 minutes.\u00a0 Then, turn off the heat and allow the electrode to cool while immersed in the solution before resuming testing.\u00a0 The last step to try, if boiling is unsuccessful, is the physical, abrasive cleaning of the liquid junction itself.\u00a0 Place a piece of #600 Emory paper on a flat surface and place a drop of water on the Emory paper.\u00a0 Placing the liquid junction perpendicular to the paper, rotate it in a circular fashion against the paper.\u00a0 Note, this cleaning method should be only as\u00a0a last resort. Because, sanding the liquid junction will severely shorten the life of the reference electrode.<\/p>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>\u672c\u6587\u65e8\u5728\u5411\u7528\u6237\u4ecb\u7ecd\u7535\u6781\u6d4b\u91cf\u4e2d\u6700\u91cd\u8981\u7684\u65b9\u9762\u4e4b\u4e00--\u53c2\u6bd4\u7535\u6781\u3002<\/p>","protected":false},"author":12,"featured_media":16394,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"inline_featured_image":false,"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_predictive_search_focuskw":"","_ps_exclude_item":"","_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[30],"tags":[],"class_list":["post-14327","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-insights"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.1 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Reference Electrode: Nature and Role - AlpHa Measure<\/title>\n<meta name=\"description\" content=\"This article aims to educate the user about one of the most important aspects of electrode measurements - Reference Electrodes.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/alpha-measure.com\/zh\/reference-electrode-nature-and-role-124\/\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Reference Electrode: Nature and Role\" \/>\n<meta property=\"og:description\" content=\"This article aims to educate the user about one of the most important aspects of electrode measurements \u2013 Reference Electrodes. They are the source of most difficulties you encounter while performing measurements, and more specifically, the reference electrode\u2019s liquid junction.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/alpha-measure.com\/zh\/reference-electrode-nature-and-role-124\/\" \/>\n<meta property=\"og:site_name\" content=\"AlpHa Measure\" \/>\n<meta property=\"article:published_time\" content=\"2023-10-25T16:02:47+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-03-26T15:52:50+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/alpha-measure.com\/wp-content\/uploads\/2023\/10\/Reference-Electrode-3x2-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"600\" \/>\n\t<meta property=\"og:image:height\" content=\"400\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"AlpHa Measurement Solutions\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u4f5c\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"AlpHa Measurement Solutions\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data2\" content=\"14 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/alpha-measure.com\\\/zh\\\/reference-electrode-nature-and-role-124\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/alpha-measure.com\\\/zh\\\/reference-electrode-nature-and-role-124\\\/\"},\"author\":{\"name\":\"AlpHa Measurement Solutions\",\"@id\":\"https:\\\/\\\/alpha-measure.com\\\/#\\\/schema\\\/person\\\/d40fc86a2532c062070f239738bb2157\"},\"headline\":\"Reference Electrode: Nature and Role\",\"datePublished\":\"2023-10-25T16:02:47+00:00\",\"dateModified\":\"2025-03-26T15:52:50+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/alpha-measure.com\\\/zh\\\/reference-electrode-nature-and-role-124\\\/\"},\"wordCount\":2629,\"publisher\":{\"@id\":\"https:\\\/\\\/alpha-measure.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/alpha-measure.com\\\/zh\\\/reference-electrode-nature-and-role-124\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/alpha-measure.com\\\/wp-content\\\/uploads\\\/2023\\\/10\\\/Reference-Electrode-3x2-1.jpg\",\"articleSection\":[\"Insights\"],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/alpha-measure.com\\\/zh\\\/reference-electrode-nature-and-role-124\\\/\",\"url\":\"https:\\\/\\\/alpha-measure.com\\\/zh\\\/reference-electrode-nature-and-role-124\\\/\",\"name\":\"Reference Electrode: Nature and Role - AlpHa Measure\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/alpha-measure.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/alpha-measure.com\\\/zh\\\/reference-electrode-nature-and-role-124\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/alpha-measure.com\\\/zh\\\/reference-electrode-nature-and-role-124\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/alpha-measure.com\\\/wp-content\\\/uploads\\\/2023\\\/10\\\/Reference-Electrode-3x2-1.jpg\",\"datePublished\":\"2023-10-25T16:02:47+00:00\",\"dateModified\":\"2025-03-26T15:52:50+00:00\",\"description\":\"This article aims to educate the user about one of the most important aspects of electrode measurements - Reference Electrodes.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/alpha-measure.com\\\/zh\\\/reference-electrode-nature-and-role-124\\\/#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/alpha-measure.com\\\/zh\\\/reference-electrode-nature-and-role-124\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/alpha-measure.com\\\/zh\\\/reference-electrode-nature-and-role-124\\\/#primaryimage\",\"url\":\"https:\\\/\\\/alpha-measure.com\\\/wp-content\\\/uploads\\\/2023\\\/10\\\/Reference-Electrode-3x2-1.jpg\",\"contentUrl\":\"https:\\\/\\\/alpha-measure.com\\\/wp-content\\\/uploads\\\/2023\\\/10\\\/Reference-Electrode-3x2-1.jpg\",\"width\":600,\"height\":400,\"caption\":\"black and white reference electrode diagram\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/alpha-measure.com\\\/zh\\\/reference-electrode-nature-and-role-124\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/alpha-measure.com\\\/zh\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Reference Electrode: Nature and Role\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/alpha-measure.com\\\/#website\",\"url\":\"https:\\\/\\\/alpha-measure.com\\\/\",\"name\":\"AlpHa Measure\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/alpha-measure.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/alpha-measure.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/alpha-measure.com\\\/#organization\",\"name\":\"AlpHa Measure\",\"url\":\"https:\\\/\\\/alpha-measure.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/alpha-measure.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/alpha-measure.com\\\/wp-content\\\/uploads\\\/2022\\\/12\\\/AlpHa-MS-Logo-White_Enpro-small.png\",\"contentUrl\":\"https:\\\/\\\/alpha-measure.com\\\/wp-content\\\/uploads\\\/2022\\\/12\\\/AlpHa-MS-Logo-White_Enpro-small.png\",\"width\":374,\"height\":164,\"caption\":\"AlpHa Measure\"},\"image\":{\"@id\":\"https:\\\/\\\/alpha-measure.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/alpha-measure.com\\\/#\\\/schema\\\/person\\\/d40fc86a2532c062070f239738bb2157\",\"name\":\"AlpHa Measurement Solutions\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8fdc2882f7b267ff673ccf1409c9aec26e3e0f932ffccb57947286cb1e2ce67c?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8fdc2882f7b267ff673ccf1409c9aec26e3e0f932ffccb57947286cb1e2ce67c?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8fdc2882f7b267ff673ccf1409c9aec26e3e0f932ffccb57947286cb1e2ce67c?s=96&d=mm&r=g\",\"caption\":\"AlpHa Measurement Solutions\"},\"url\":\"https:\\\/\\\/alpha-measure.com\\\/zh\\\/author\\\/alpha-measurement\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Reference Electrode: Nature and Role - AlpHa Measure","description":"This article aims to educate the user about one of the most important aspects of electrode measurements - Reference Electrodes.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/alpha-measure.com\/zh\/reference-electrode-nature-and-role-124\/","og_locale":"zh_CN","og_type":"article","og_title":"Reference Electrode: Nature and Role","og_description":"This article aims to educate the user about one of the most important aspects of electrode measurements \u2013 Reference Electrodes. They are the source of most difficulties you encounter while performing measurements, and more specifically, the reference electrode\u2019s liquid junction.","og_url":"https:\/\/alpha-measure.com\/zh\/reference-electrode-nature-and-role-124\/","og_site_name":"AlpHa Measure","article_published_time":"2023-10-25T16:02:47+00:00","article_modified_time":"2025-03-26T15:52:50+00:00","og_image":[{"width":600,"height":400,"url":"https:\/\/alpha-measure.com\/wp-content\/uploads\/2023\/10\/Reference-Electrode-3x2-1.jpg","type":"image\/jpeg"}],"author":"AlpHa Measurement Solutions","twitter_card":"summary_large_image","twitter_misc":{"\u4f5c\u8005":"AlpHa Measurement Solutions","\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"14 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/alpha-measure.com\/zh\/reference-electrode-nature-and-role-124\/#article","isPartOf":{"@id":"https:\/\/alpha-measure.com\/zh\/reference-electrode-nature-and-role-124\/"},"author":{"name":"AlpHa Measurement Solutions","@id":"https:\/\/alpha-measure.com\/#\/schema\/person\/d40fc86a2532c062070f239738bb2157"},"headline":"Reference Electrode: Nature and Role","datePublished":"2023-10-25T16:02:47+00:00","dateModified":"2025-03-26T15:52:50+00:00","mainEntityOfPage":{"@id":"https:\/\/alpha-measure.com\/zh\/reference-electrode-nature-and-role-124\/"},"wordCount":2629,"publisher":{"@id":"https:\/\/alpha-measure.com\/#organization"},"image":{"@id":"https:\/\/alpha-measure.com\/zh\/reference-electrode-nature-and-role-124\/#primaryimage"},"thumbnailUrl":"https:\/\/alpha-measure.com\/wp-content\/uploads\/2023\/10\/Reference-Electrode-3x2-1.jpg","articleSection":["Insights"],"inLanguage":"zh-Hans"},{"@type":"WebPage","@id":"https:\/\/alpha-measure.com\/zh\/reference-electrode-nature-and-role-124\/","url":"https:\/\/alpha-measure.com\/zh\/reference-electrode-nature-and-role-124\/","name":"Reference Electrode: Nature and Role - AlpHa Measure","isPartOf":{"@id":"https:\/\/alpha-measure.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/alpha-measure.com\/zh\/reference-electrode-nature-and-role-124\/#primaryimage"},"image":{"@id":"https:\/\/alpha-measure.com\/zh\/reference-electrode-nature-and-role-124\/#primaryimage"},"thumbnailUrl":"https:\/\/alpha-measure.com\/wp-content\/uploads\/2023\/10\/Reference-Electrode-3x2-1.jpg","datePublished":"2023-10-25T16:02:47+00:00","dateModified":"2025-03-26T15:52:50+00:00","description":"This article aims to educate the user about one of the most important aspects of electrode measurements - Reference Electrodes.","breadcrumb":{"@id":"https:\/\/alpha-measure.com\/zh\/reference-electrode-nature-and-role-124\/#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/alpha-measure.com\/zh\/reference-electrode-nature-and-role-124\/"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/alpha-measure.com\/zh\/reference-electrode-nature-and-role-124\/#primaryimage","url":"https:\/\/alpha-measure.com\/wp-content\/uploads\/2023\/10\/Reference-Electrode-3x2-1.jpg","contentUrl":"https:\/\/alpha-measure.com\/wp-content\/uploads\/2023\/10\/Reference-Electrode-3x2-1.jpg","width":600,"height":400,"caption":"black and white reference electrode diagram"},{"@type":"BreadcrumbList","@id":"https:\/\/alpha-measure.com\/zh\/reference-electrode-nature-and-role-124\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/alpha-measure.com\/zh\/"},{"@type":"ListItem","position":2,"name":"Reference Electrode: Nature and Role"}]},{"@type":"WebSite","@id":"https:\/\/alpha-measure.com\/#website","url":"https:\/\/alpha-measure.com\/","name":"AlpHa Measure","description":"","publisher":{"@id":"https:\/\/alpha-measure.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/alpha-measure.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/alpha-measure.com\/#organization","name":"AlpHa Measure","url":"https:\/\/alpha-measure.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/alpha-measure.com\/#\/schema\/logo\/image\/","url":"https:\/\/alpha-measure.com\/wp-content\/uploads\/2022\/12\/AlpHa-MS-Logo-White_Enpro-small.png","contentUrl":"https:\/\/alpha-measure.com\/wp-content\/uploads\/2022\/12\/AlpHa-MS-Logo-White_Enpro-small.png","width":374,"height":164,"caption":"AlpHa Measure"},"image":{"@id":"https:\/\/alpha-measure.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/alpha-measure.com\/#\/schema\/person\/d40fc86a2532c062070f239738bb2157","name":"AlpHa \u6d4b\u91cf\u89e3\u51b3\u65b9\u6848","image":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/secure.gravatar.com\/avatar\/8fdc2882f7b267ff673ccf1409c9aec26e3e0f932ffccb57947286cb1e2ce67c?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/8fdc2882f7b267ff673ccf1409c9aec26e3e0f932ffccb57947286cb1e2ce67c?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8fdc2882f7b267ff673ccf1409c9aec26e3e0f932ffccb57947286cb1e2ce67c?s=96&d=mm&r=g","caption":"AlpHa Measurement Solutions"},"url":"https:\/\/alpha-measure.com\/zh\/author\/alpha-measurement\/"}]}},"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/alpha-measure.com\/wp-content\/uploads\/2023\/10\/Reference-Electrode-3x2-1.jpg","_links":{"self":[{"href":"https:\/\/alpha-measure.com\/zh\/wp-json\/wp\/v2\/posts\/14327","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/alpha-measure.com\/zh\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/alpha-measure.com\/zh\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/alpha-measure.com\/zh\/wp-json\/wp\/v2\/users\/12"}],"replies":[{"embeddable":true,"href":"https:\/\/alpha-measure.com\/zh\/wp-json\/wp\/v2\/comments?post=14327"}],"version-history":[{"count":28,"href":"https:\/\/alpha-measure.com\/zh\/wp-json\/wp\/v2\/posts\/14327\/revisions"}],"predecessor-version":[{"id":19129,"href":"https:\/\/alpha-measure.com\/zh\/wp-json\/wp\/v2\/posts\/14327\/revisions\/19129"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/alpha-measure.com\/zh\/wp-json\/wp\/v2\/media\/16394"}],"wp:attachment":[{"href":"https:\/\/alpha-measure.com\/zh\/wp-json\/wp\/v2\/media?parent=14327"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/alpha-measure.com\/zh\/wp-json\/wp\/v2\/categories?post=14327"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/alpha-measure.com\/zh\/wp-json\/wp\/v2\/tags?post=14327"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}